Caisson problem

Concrete Construction, June, 2004

Q. We are installing some concrete caissons using an ordinary caisson mix (similar to CDOT Class BZ) designed for 6- to 8-inch slump placements. The caissons range from 30 to 60 inches in diameter and are 20 to 25 feet deep. We have not encountered any water during drilling. The concrete is being placed with a tremie, with the top 10 feet being vibrated after the tremie is withdrawn. The problem is that sometime before the concrete hardens a vertical subsidence of 3 to 4 inches occurs in the middle of the caisson. That leaves anchor bolts placed in the plastic concrete no longer in the correct position. Why is this occurring?

A. This is simply consolidation subsidence in the lower, unconsolidated portion of the caisson. The tremie-delivered concrete isn't vibrated and it settles as the mass of concrete above it forces air from the concrete in the lower portion of the caisson.

To avoid the subsidence, you can either get rid of the tremie, allowing the freefall of the concrete to supply the necessary consolidation to the lower caisson section, or you can supply vibration to the caisson's full depth. Obviously, it is simpler to opt for allowing the concrete to fall freely into the caisson.

A 1970 study sponsored by The International Association of Foundation Drilling determined that the free fall of concrete to depths of 120 feet was possible without segregation and actually produced superior strengths due to the high degree of consolidation achieved from the energy supplied by the impact of the free falling concrete. Although your application is not as extreme, you should still observe the primary cautions for this type of placement: a quality concrete mixture, an unobstructed vertical drop, and protection of soil side walls to prevent cave-ins.

As far as the anchor bolts are concerned, you should also consider setting them in a plywood template. That would help maintain their correct locations as the concrete set and would be a good practice even if yon weren't concerned about subsidence.

COPYRIGHT 2004 Hanley-Wood, Inc.
COPYRIGHT 2004 Gale Group

 

BNET TalkbackShare your ideas and expertise on this topic

Please add your comment:

  1. You are currently: a Guest |
  2.  

Basic HTML tags that work in comments are: bold (<b></b>), italic (<i></i>), underline (<u></u>), and hyperlink (<a href></a)

advertisement
Click Here
advertisement
  • Click Here
  • Click Here
  • Click Here
advertisement

Content provided in partnership with Thompson Gale