Accuracy tests for simulations of VAV dual-duct, single-zone, four-pipe fan-coil, and four-pipe induction air-handling systems

ASHRAE Transactions, July, 2006 by G.K. Yuill, J.S. Haberl, J.S. Caldwell

CONCLUSIONS

The heating and cooling coil loads tabulated here provide the BEA program user and the program developer with a method of checking the performance of that segment of a BEA program that simulates air-side systems. By comparing the output of the program with the data presented in this paper, potential errors in a BEA program can quickly be identified. A companion paper provides similar accuracy tests for constant volume, dual-duct and variable volume air-handling systems.

ACKNOWLEDGMENTS

The work described here was supported by ASHRAE Research Project RP-865.

REFERENCES

ASHRAE. 1993. 1993 ASHRAE Handbook--Fundamentals. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.

ASHRAE. 1995. 1995 ASHRAE Handbook--HVAC Applications. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.

BSL. 1999. BLAST 3.0 Users Manual. Urbana-Champaign, IL: Building Systems Laboratory, Department of Mechanical and Industrial Engineering, University of Illlinois.

Haberl, J., N. Saman, and T. Bou-Saada. 2002. Air-side energy use calculations for seven HVAC systems: Dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), constant volume with reheat (CAVRH); variable volume with reheat (VAVRH), four pipe fan coil Unit (FC), four pipe induction unit (FI), and single zone (SZ) systems. Energy Systems Laboratory Report, ESL-TR-01/02-02, Texas A & M University, College Station, Texas.

Knebel, D.E. 1983. Simplified energy analysis using the modified bin method. ASHRAE.

Winkelman, F.C., B.E. Birdsall, W.F. Buhl, K.L. Ellington, A.E. Erdem, J.J. Hirsch, and S. Gates. 1993. DOE-2 Supplement, Version 2.1E, LBL-34947. Lawrence Berkeley National Laboratory, Berkeley, California.

Yuill, G.K., and J.S. Haberl. 2002. Development of accuracy tests for mechanical system simulation, Final report (RP-865). American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta.

Yuill, G.K., J.S. Haberl, and J.S. Caldwell. 2005. Accuracy tests for simulations of constant volume, dual duct, and variable volume air-handling systems. ASHRAE Transactions 111(2).

G.K. Yuill, PhD, PEng

Fellow ASHRAE

J.S. Haberl, PhD, PE

Member ASHRAE

J.S. Caldwell

Associate Member ASHRAE

G.K. Yuill is director of the Architectural Engineering Program at the University of Nebraska, Lincoln. J.S. Haberl is an associate professor of architecture at Texas A & M University, College Station, Texas. J.S. Caldwell is an associate principal at James Posey Associates, Baltimore, Maryland.


 

BNET TalkbackShare your ideas and expertise on this topic

Please add your comment:

  1. You are currently: a Guest |
  2.  

Basic HTML tags that work in comments are: bold (<b></b>), italic (<i></i>), underline (<u></u>), and hyperlink (<a href></a)

advertisement
Click Here
advertisement
  • Click Here
  • Click Here
  • Click Here
advertisement

Content provided in partnership with Thompson Gale