Strain-Gauge Measurement of Weight of Fluid in a Tank
NASA Tech Briefs, Mar 2004
This method is nonintrusive and independent of the nature of the fluid.
Stennis Space Center, Mississippi
A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods).
The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation.
One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable.
A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).
The fiber-optic sensors are reliable and at least as accurate as the foil sensors (possibly more). The fiber-optic system consists of one or more sensors mounted on the structure, a temperature sensor also mounted on the structure, and a reference fiber-optic sensor mounted on a plate made of the same material as the tank-supporting legs, that is not subjected to any mechanical load. An important element to consider is the thermal deformation of the structure, which is not going to be exactly the same as that of the reference plate. This is because the structure has appendages (pipes, etc.) that must be taken into account for temperature compensation. The procedure to calculate a compensated measurement (a measurement reflecting the mass contents of the tank) using the fiber-optic system is as follows: First, one must characterize the structure as it deforms due solely to thermal effects by taking measurements over its operating temperature range, when the tank is empty. During this characterization procedure, deformation and temperature measurements are taken from the sensors attached to the structure (strain and temperature) and the sensor attached to the reference plate (strain). With this information, a tabulated or graphical tool is developed such that at any given temperature, the reference signal is subtracted from the structural signal, and further modified by a value that depends on the structure's temperature. Note that the characterization of the structure as it deforms due to temperature variations may also be done by analytical methods that can model the process. In that case, the experimental characterization is not needed.
It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank-supporting legs, larger gauges that measure larger deformations, or other methods to increase the strain in some part of the tank support structure.
This work was done by Jorge Figueroa, William St. Cyr, and Shamim Rahmart of Stennis Space Center and Gregory McVay, David Van Dyke, William Mitchell, and Lester Langford of Lockheed Martin Corp.
Inquiries concerning rights for the commercial use of this invention should be addressed to the Intellectual Property Manager, Stennis Space Center, (228) 688-1929. Refer to SSC-00187.
- 5 Rules for Immediate Annuities
- Death in the Family: 12 Things to Do Now
- Dumbest Things You Do With Your Money
- 6 Online Networking Mistakes to Avoid
- 401(k) Mistakes to Avoid
- 5 Economic Scenarios to Keep You Up at Night
- The Real ‘Best Places to Retire’
- Best Credit Cards for You
- 12 Tough Questions to Ask Your Parents
- The Real ‘Best Colleges’
- Home Buyer Tax Credit: How to Cash In
- Why You Shouldn't Bash Cash
- 8 Phony 'Bargains' and Better Alternatives
- Danger: 3 Debit Card Scams to Avoid
- 6 Myths About Gas Mileage
- 29 Fees We Hate Most
- Quick and Easy Ways to Boost Returns
- Best Stocks to Buy Now
- Lower Your Taxes: 10 Moves to Make Now
- New Jobs: 8 Lessons from Real-Life Career Switchers
- The New Job Market: Who Wins and Who Loses?
- Health Care Reform's Public Option: Everything You Need to Know
- Volunteer Work When Unemployed: Should You Work for Free?
- Whose Recovery Is This?
- Long-Term-Care Insurance: 4 Biggest Risks to Avoid
Content provided in partnership with
Most Recent Reference Articles
- A Maryland state trooper gave Erik Bonstrom an $80 ticket for driving too slowly
- In California, postal worker Dean Hudson has been found guilty
- Alec Loorz, the 15-year-old founder of Kids vs. Global Warming and recent Brower Youth Award recipient, went to Congress in November for a press conference with Senators Barbara Boxer and John Kerry, who are championing legislation to stabilize US greenho
- Foreign exchange
- The buzz on bees
Most Recent Reference Publications
Most Popular Reference Articles
- Credit card debt on college campuses: causes, consequences, and solutions
- 9 questions to ask your new lover: what you were afraid to ask, but always wanted to know
- How Tyler Perry rose from homelessness to a $5 million mansion
- Rejoice anyway - Zephaniah 3:14-20, Philippians 4:4-7 - Living by the Word - Column
- Living by the word