Article Results (Showing 1 - 10 of 10) RSS Alert
» Did you mean: Steven C Kazmierczak?
-
Correction Factors for Estimating Potassium Concentrations in Samples With In Vitro Hemolysis: A Detriment to Patient Safety
Context.-Correction factors have been proposed for estimating true potassium concentrations in blood samples with evidence of in vitro hemolysis. ...
Archives of Pathology & Laboratory Medicine, 06/01/09 by Mansour, Mai M H; Azzazy, Hassan M E; Kazmierczak, Steven C · More from publication -
Answering your questions; low B12 determination
Q I have a physician telling me that all our B12 determinations are low. The low B12 result does not agree with the clinical picture. What are some...
Medical Laboratory Observer, 12/01/06 by Steven C. Kazmierczak · More from publication -
High CK in asymptomatic woman
Q A 79-year-old female out-patient has a repeatedly high total CK (900 +/-; reference <215 U/L). Her clinician obtained an ALD (aldolase), which...
Medical Laboratory Observer, 06/01/05 by Steven C. Kazmierczak · More from publication -
Pipette QC
Q I am in a doctor's office lab. I need to do my MLA pipette QC. What is the easiest way to go about verification for my MLA pipettes? I used to do...
Medical Laboratory Observer, 04/01/05 by Steven C. Kazmierczak · More from publication -
Glycolysis and specimen storage
Q Our laboratory frequently performs chemistry tests on specimens collected on a mobile basis. These specimens may not be centrifuged for several...
Medical Laboratory Observer, 04/01/05 by Steven C. Kazmierczak · More from publication -
High iron saturation, normal ferritin
Q What would cause a woman to have 100% iron saturation with a low normal ferritin? She was diagnosed with hemachromatosis 10 to 15 years ago and...
Medical Laboratory Observer, 01/01/05 by Steven C. Kazmierczak · More from publication -
C-reactive protein as a cardiac test
Q What is the current role of high-sensitivity C-reactive protein in cardiac testing in the laboratory? Is it routinely used? How is it used with...
Medical Laboratory Observer, 12/01/04 by Steven C. Kazmierczak · More from publication -
Low pH control
Q I am having a difficult time answering several questions on the CAP checklist for blood gases. At our hospital, it is not uncommon to have pHs in...
Medical Laboratory Observer, 11/01/04 by Steven C. Kazmierczak · More from publication -
Test validation
I have been a tech for 32 years, am of above-average intelligence, and I still do not understand CLIA's latest requirement for test validation. I...
Medical Laboratory Observer, 06/01/04 by Steven C. Kazmierczak · More from publication -
Liquid calibrators for instrument
Q Olympus has recently changed its calibrator configuration to a lypholized material that is not stable enough to fit our situation. We are a small...
Medical Laboratory Observer, 04/01/04 by Steven C. Kazmierczak · More from publication